Contact Us

AI and high-performance computing architectures increasingly combine processors, accelerators, memory-facing logic, and other specialized functions across multiple die. In these systems, the chiplet interconnect is not simply a connection between two pieces of silicon. It becomes part of the larger system architecture that must carry different traffic types, support demanding bandwidth requirements, and integrate with the protocols already used inside each chiplet.

Universal Chiplet Interconnect Express, or UCIe, provides a standardized die-to-die foundation for these multi-die systems. But implementing UCIe does not necessarily mean every chiplet needs the same combination of IP.

One subsystem may need AXI connectivity. Another may require coherent CHI or CXL communication. PCIe may be appropriate for another part of the architecture, while a streaming subsystem may rely on CXS.

This makes a modular UCIe IP stack especially useful for AI and HPC chiplet designs. Rather than treating the interconnect as one fixed block, engineering teams can combine UCIe Controller IP, the protocol-specific Bridge IP required by the architecture, and UCIe Verification IP around the actual needs of the system.

SmartDV’s UCIe IP for Next-Generation Chiplet Designs portfolio is structured around this type of controller, bridge, and verification approach.

Why a Modular UCIe Stack Matters for AI and HPC

AI and HPC systems are increasingly heterogeneous. A single package may combine general-purpose compute, specialized acceleration, memory interfaces, coherent fabrics, high-speed I/O, and other functions that were previously integrated into one large monolithic SoC.

Those functions do not necessarily communicate using the same protocol.

An accelerator subsystem may use AXI. A coherent processor fabric may use CHI. A memory or accelerator connection may use CXL. PCIe may remain important for I/O-oriented functions. CXS may be used for high-bandwidth streaming communication.

UCIe provides the common die-to-die transport foundation, while the controller and bridge architecture determines how those different protocol domains connect to it.

A modular approach allows engineering teams to begin with the UCIe functionality required for the die-to-die connection and add the protocol interfaces that match the surrounding system rather than treating every chiplet as though it has identical connectivity requirements.

The Core Layers of a Modular UCIe IP Stack

A modular UCIe solution combines two implementation components with a complementary verification environment:

  • UCIe Controller IP for the die-to-die protocol stack
  • Protocol-specific Bridge IP for connecting existing SoC protocol domains into UCIe
  • Verification IP for validating the UCIe interface and associated system behavior

These components solve related problems, but they serve different roles within the design.

For a deeper explanation of the distinction between the first two layers, see UCIe Controller IP vs. UCIe Bridge IP: What Does a Chiplet Design Need?

Start with the UCIe Controller

The UCIe controller provides the core die-to-die protocol functionality required by the chiplet connection.

SmartDV currently provides UCIe 2.x Controller IP and UCIe 3.x Controller IP.

The UCIe 2.x Controller supports operation through 32 GT/s, while the UCIe 3.x Controller extends operation through 64 GT/s and adds capabilities including runtime recalibration, priority sideband messaging, and power-saving enhancements such as L2 optimization.

For teams deciding which controller generation is appropriate for a new platform, see UCIe 2.x vs. UCIe 3.x: What Changed for Chiplet Interconnect Design?

The controller establishes the UCIe foundation, but the system architecture still determines how traffic reaches that controller.

Add Only the Protocol Bridges the Architecture Requires

The next layer is the connection between UCIe and the protocol environment used inside the chiplet.

SmartDV provides UCIe Bridge IP for AXI, CHI, CXL, PCIe, and CXS. Each bridge addresses a different system architecture and traffic model.

AXI for SoC and Accelerator Data Paths

AXI is commonly used across SoC subsystems, accelerators, memory-facing logic, and other internal data paths.

SmartDV’s AXI to UCIe Bridge IP provides AXI connectivity into the UCIe die-to-die architecture. The current IP supports AMBA AXI5 with backward compatibility for AXI4 and AXI3 and supports UCIe operation through 64 GT/s.

CHI for Coherent Processor Architectures

Systems built around coherent processor and cache fabrics may require CHI behavior to extend across chiplet boundaries.

SmartDV’s CHI to UCIe Bridge IP supports AMBA 5 CHI communication across UCIe, including Request, Home, and Slave node types.

CXL for Coherent Accelerator and Memory Connectivity

CXL is increasingly relevant to AI and HPC systems where processors, accelerators, and memory resources need coherent connectivity.

SmartDV’s CXL to UCIe Bridge IP supports CXL.io, CXL.cache, and CXL.mem traffic across UCIe.

PCIe for High-Speed I/O-Oriented Functions

PCI Express remains an important interface for accelerators, networking, storage, and other high-speed system functions.

SmartDV’s PCIe to UCIe Bridge IP connects PCIe Root Complex and Endpoint functionality to a UCIe die-to-die architecture.

CXS for High-Bandwidth Streaming

Systems using AMBA CXS for streaming communication can connect that protocol environment into UCIe through SmartDV’s CXS to UCIe Bridge IP.

For a detailed comparison of these protocol options, see UCIe Bridge IP Explained: Connecting AXI, CHI, CXL, PCIe, and CXS Across Chiplets.

A Modular Stack Can Support Different Chiplets Differently

A heterogeneous package does not have to use the same protocol connection for every chiplet.

Consider a multi-die AI or HPC platform containing several types of functions:

  • A compute die built around a coherent processor fabric
  • An accelerator die using a high-bandwidth AXI data path
  • A memory-oriented die using CXL connectivity
  • An I/O-oriented die using PCIe

Each subsystem can have different protocol requirements while using UCIe as the common die-to-die interconnect.

In that type of system, the architecture might use CHI-to-UCIe connectivity for one chiplet and AXI-to-UCIe or CXL-to-UCIe connectivity for another. The value of the modular approach is that protocol connectivity can follow the role of the chiplet rather than requiring every die to adopt the same host-side interface.

Modularity Also Matters Across Product Generations

AI and HPC designs often evolve into product families rather than remaining one fixed implementation.

A first-generation accelerator may require one set of protocol connections, while a later product adds another chiplet, changes the internal fabric, increases UCIe performance, or introduces another protocol domain.

That makes configurability and reuse important considerations when selecting semiconductor IP.

SmartDV’s broader approach to configurable IP is described in Flexible IP Licensing and Customizable IP: What SoC Teams Should Consider. That article discusses how Design IP configuration, reuse, licensing, and verification strategy can be aligned with different project and product-family requirements.

The same principle applies to a UCIe stack: engineering teams should consider not only what the first device requires, but how the controller, bridge, and verification architecture may need to evolve across later designs.

Design IP and Verification IP Serve Complementary Roles

A modular UCIe stack includes both implementation and verification requirements.

Controller and Bridge IP become part of the functional chip design. Verification IP provides reusable infrastructure for validating that the implementation behaves correctly.

SmartDV’s existing FAQ What Is the Difference Between Verification IP and Design IP? explains this distinction in more detail.

For a UCIe architecture, this means the design stack and verification stack should be planned together. Adding another protocol bridge, supporting another link speed, or enabling another configuration can also expand the scenarios that need to be verified.

Key Technical Challenges in a Modular UCIe Architecture

Modularity gives system architects flexibility, but it also increases the importance of validating the boundaries between different layers of the system.

End-to-End Protocol Behavior

Traffic may begin in AXI, CHI, CXL, PCIe, or CXS, pass through a protocol bridge, enter the UCIe controller, cross the die-to-die link, and then be consumed elsewhere in the system.

The complete path must preserve the behavior required by the source and destination protocols.

Different Traffic Models

Streaming traffic, coherent transactions, I/O traffic, memory-oriented communication, and processor-fabric transactions place different demands on the surrounding architecture.

A modular UCIe implementation therefore needs to be evaluated in the context of the traffic each chiplet is expected to generate and receive.

Link and Protocol Configuration

Lane configuration, Flit formats, protocol mapping, sideband communication, retry behavior, reset handling, and other UCIe functions interact with the protocol bridges around them.

Configuration should be validated as a system rather than assuming that correct operation of each individual block guarantees correct end-to-end behavior.

Debug Across IP Boundaries

When a failure occurs in a multi-die system, the problem may originate in the source subsystem, protocol bridge, UCIe controller, link behavior, receiving subsystem, or configuration between those components.

Protocol-aware verification and clear visibility across these boundaries become especially important as the IP stack grows.

How Verification Teams Should Approach a Modular UCIe Stack

Verification should reflect the complete architecture rather than testing the UCIe controller, bridges, and surrounding interfaces only as isolated components.

A verification plan should account for:

  • Each UCIe revision the product intends to support
  • Supported link speeds and lane configurations
  • The protocol bridges used in the design
  • Normal and stressed traffic conditions
  • Ordering and flow-control behavior
  • Link initialization and training
  • Sideband communication
  • Reset and recovery sequences
  • Error injection and retry behavior
  • Power-management behavior
  • End-to-end transaction integrity
  • Interactions between multiple chiplets and protocol domains

SmartDV’s UCIe VIP supports UCIe versions 1.0, 1.1, 2.0, and 3.0 with speeds through 64 GT/s. It also provides Flit-format coverage, link training, sideband behavior, retry and recovery support, error injection, protocol checking, and functional coverage.

For a deeper discussion of the verification requirements created by die-to-die integration, see Why UCIe Verification Is Critical for Chiplet-Based SoC Design.

Related SmartDV UCIe Products and Internal Resources

Additional UCIe resources:

Article Summary

AI and HPC chiplet systems often combine multiple types of compute, accelerator, memory, and I/O functionality within the same package. Those subsystems may use different protocol architectures even though they share the same UCIe die-to-die foundation.

A modular UCIe stack allows engineering teams to combine the components their architecture requires:

  • UCIe Controller IP provides the core die-to-die protocol functionality.
  • UCIe Bridge IP connects AXI, CHI, CXL, PCIe, or CXS protocol domains into the UCIe architecture.
  • UCIe Verification IP provides reusable infrastructure for validating UCIe behavior and system-level integration.

This approach allows different chiplets to use different protocol connections while sharing UCIe as the package-level interconnect. It also gives engineering teams a framework that can evolve as link speeds, protocol requirements, chiplet configurations, and future product generations change.

For AI and HPC teams, the important question is therefore not simply which UCIe IP product to select. It is which combination of controller, bridge, and verification technologies best matches the actual system architecture.

Frequently Asked Questions

What is a modular UCIe IP stack?
A modular UCIe IP stack combines the UCIe Controller IP required for the die-to-die connection with the protocol-specific Bridge IP and Verification IP needed by the particular system architecture. Different designs can therefore use different combinations of UCIe components rather than relying on one fixed configuration.

Why might an AI or HPC chiplet system need multiple UCIe bridges?
AI and HPC systems may contain several protocol domains. One subsystem may use AXI, another may use CHI or CXL, and another may use PCIe or CXS. Different UCIe bridges allow those protocol environments to connect to the common UCIe die-to-die infrastructure.

Does every chiplet need the same UCIe configuration?
No. The protocol, performance, lane, and feature requirements can vary according to the function of each chiplet. A modular architecture allows the UCIe implementation to be aligned with the role of the individual subsystem.

Where does UCIe Verification IP fit into the stack?
UCIe Verification IP is used to validate the UCIe implementation and related system behavior. Verification should cover link operation, Flit behavior, sideband communication, retries, errors, recovery, protocol mapping, and end-to-end interaction with the bridges and surrounding chiplet architecture.

Can a modular UCIe architecture evolve across product generations?
Yes. A modular approach can make it easier to adapt a platform as bandwidth requirements, UCIe revisions, chiplet counts, or protocol interfaces change. Engineering teams should still verify each implemented configuration and evaluate how IP licensing, customization, and reuse apply to their particular development roadmap.

Build the UCIe Stack Your AI or HPC Architecture Requires

SmartDV provides UCIe Controller IP, AXI, CHI, CXL, PCIe, and CXS Bridge IP, and UCIe Verification IP to support configurable multi-die architectures across AI, HPC, networking, data center, and other advanced SoC applications.

Explore SmartDV UCIe IP for Next-Generation Chiplet Designs to review the controller, bridge, and verification technologies available for your chiplet architecture.

See All Chiplets & Die-to-Die Interconnects